Clinical Efficacy of Transjugular Intrahepatic Portosystemic Shunt Created with Expanded Polytetrafluoroethylene-Covered Stent-Grafts: 8-mm Versus 10-mm.
Xuefeng LuoXiaoze WangYongjun ZhuXiaotan XiYing ZhaoJinlin YangXiao LiLi YangPublished in: Cardiovascular and interventional radiology (2019)
The placement of 8-mm TIPS was sufficient to decompress the portal hypertension and prevent variceal rebleeding. The use of the 8-mm stent-graft can decrease HE rates compared with 10-mm stent-graft, although no survival benefit was observed.