Microdialysis coupled with droplet microfluidics and mass spectrometry for determination of neurotransmitters in vivo with high temporal resolution.
Shane S WellsIan J BainAlec C ValentaAshley E LenhartDaniel J SteyerRobert T KennedyPublished in: The Analyst (2024)
Monitoring the concentration fluctuations of neurotransmitters in vivo is valuable for elucidating the chemical signals that underlie brain functions. Microdialysis sampling is a widely used tool for monitoring neurochemicals in vivo . The volume requirements of most techniques that have been coupled to microdialysis, such as HPLC, result in fraction collection times of minutes, thus limiting the temporal resolution possible. Further the time of analysis can become long for cases where many fractions are collected. Previously we have used direct analysis of dialysate by low-flow electrospray ionization-tandem mass spectrometry (ESI-MS/MS) on a triple quadrupole mass spectrometer to monitor acetylcholine, glutamate, and γ-amino-butyric acid to achieve multiplexed in vivo monitoring with temporal resolution of seconds. Here, we have expanded this approach to adenosine, dopamine, and serotonin. The method achieved limits of detection down to 2 nM, enabling basal concentrations of all these compounds, except serotonin, to be measured in vivo . Comparative analysis with LC-MS/MS showed accurate results for all compounds except for glutamate, possibly due to interference for this compound in vivo . Pairing this analysis with droplet microfluidics yields 11 s temporal resolution and can generate dialysate fractions down to 3 nL at rates up to 3 fractions per s from a microdialysis probe. The system is applied to multiplexed monitoring of neurotransmitter dynamics in response to stimulation by 100 mM K + and amphetamine. These applications demonstrate the suitability of the droplet ESI-MS/MS method for monitoring short-term dynamics of up to six neurotransmitters simultaneously.
Keyphrases
- ms ms
- tandem mass spectrometry
- high performance liquid chromatography
- mass spectrometry
- liquid chromatography
- ultra high performance liquid chromatography
- single cell
- high resolution
- simultaneous determination
- solid phase extraction
- gas chromatography
- high throughput
- single molecule
- liquid chromatography tandem mass spectrometry
- peritoneal dialysis
- molecularly imprinted
- white matter
- loop mediated isothermal amplification
- uric acid
- real time pcr
- subarachnoid hemorrhage
- brain injury