Stability indicating liquid chromatographic method for simultaneous quantification of betamethasone valerate and tazarotene in in vitro and ex vivo studies of complex nanoformulation.

Vamshi Krishna RapalliGautam SinghviSrividya GorantlaTejashree WaghuleSunil Kumar DubeyRanendra Narayan SahaMd Saquib HasnainAmit Kumar Nayak
Published in: Journal of separation science (2019)
Low-potency corticosteroid betamethasone valerate and vitamin-A tazarotene are used in combination for effective treatment of psoriasis. There is no robust high-performance liquid chromatography analytical technique available for simultaneous estimation of betamethasone valerate and tazarotene in conventional and nanocarriers based formulations. A simple, accurate, robust isocratic high-performance liquid chromatography method was developed for simultaneous estimation of betamethasone valerate and tazarotene in topical pharmaceutical formulations. The developed method was validated as per the regulatory guidelines. The validated method was linear over the concentration range of 150-6000 ng/mL (r2  > 0.999) at 239 nm wavelength. Limits of detection and quantification of two analytes were 50 and 150 ng/mL, respectively. The %relative standard deviation for intraday and interday precision was less than 2%. The method was also evaluated in the presence of forced degradation conditions. The developed method was successfully applied for in vitro and ex vivo drug release studies of in-house designed nanoformulations.