Login / Signup

A System in Package Based on a Piezoelectric Micromachined Ultrasonic Transducer Matrix for Ranging Applications.

Alexandre RobichaudDominic DeslandesPaul-Vahe CicekFrederic Nabki
Published in: Sensors (Basel, Switzerland) (2021)
This paper proposes a system in package (SiP) for ultrasonic ranging composed of a 4 × 8 matrix of piezoelectric micromachined ultrasonic transducers (PMUT) and an interface integrated circuit (IC). The PMUT matrix is fabricated using the PiezoMUMPS process and the IC is implemented in the AMS 0.35 µm technology. Simulation results for the PMUT are compared to the measurement results, and an equivalent circuit has been derived to allow a better approximation of the load of the PMUT on the IC. The control circuit is composed of a high-voltage pulser to drive the PMUT for transmission and of a transimpedance amplifier to amplify the received echo. The working frequency of the system is 1.5 MHz.