Determination of thermal sensation levels for Koreans based on perceived temperature and climate chamber experiments with hot and humid settings.
Misun KangKyu Rang KimJoo-Young LeeJu-Young ShinPublished in: International journal of biometeorology (2022)
People perceive thermal sensation differently despite the same temperature value of thermal comfort index depending on various factors such as climate, culture, and physiological characteristics. The use of the thermal comfort index without optimization may lead to biases in assessment of thermal stress and sensation. This study aims to derive the perceived temperature (PT) ranges of thermal sensation levels related to heat stress for Koreans. The experiments were designed using a controlled environmental chamber to derive the PT ranges and were performed with subjects who are residents of Seoul, South Korea. The experiments were carried out in the summers of 2017 and 2018, and the thermal sensation votes were surveyed from 19 subjects whose mean age, height, weight, and body mass index were 22.5 years, 171 cm, 72 kg, and 23 kg⋅m -2 , respectively. The derived PT ranges for Koreans led to a better performance than the reference PT ranges for Germans based on the results of validation. The thresholds of 'Warm,' 'Hot,' and 'Very hot' thermal sensation classes for Koreans were 28 °C, 36 °C, and 43 °C, respectively: higher than those for Germans. The results indicate that Koreans may have higher heat resistance or lower heat sensitivity than Germans.