Inhalation Profiles Through a Dry Powder Inhaler: Relation Between Inhalation Technique and Spirometric Measures.
Agata DoroszTomasz UrbankowskiKrzysztof ZielińskiMarcin MichnikowskiRafał KrenkeArkadiusz MoskalPublished in: Journal of aerosol medicine and pulmonary drug delivery (2021)
Background: The understanding of the real flow profiles through a dry powder inhaler (DPI), generated by asthma patients, is a prerequisite for satisfactory drug delivery to the lungs. The aims of the study were to assess the relationship between spirometric measures and inhalation profiles through a low-resistance DPI, and to compare parameters of those profiles between optimal and suboptimal inhalation technique type. Methods: Both healthy adult volunteers and patients with asthma were included in the study. Spirometry was conducted along with modified flow-volume test to detect expiratory levels (maximum "100%" exhalation to residual volume [RV] and halfway "50%" to RV). These were the reference levels of the depth of exhalation for each patient to simulate the effect of incomplete exhalation. Individual inhalation profiles were recorded using spirometry in-house software as the volumetric airflow through the inhaler versus time. Inspiratory flow parameters were extracted: time to peak inspiratory flow through inhaler (PIFinh), time at which peak inspiratory flow occurs (tPIFinh), total inhalation time (T), and inhaled volume during maneuver (V). Results and Conclusions: There are significant relationships between spirometric indices and parameters of inhalation through a low-resistance, cyclohaler-type DPI (assessed by single-factor analysis of Spearman's rank correlation coefficient). Multiple regression models were constructed, predicting inspiratory flow parameters (including spirometric indices, demographic parameters, and inhaler's usage history as determinants). The exhalation halfway to RV before inhalation did not affect significantly PIFinh and tPIFinh (and, thus, initial flow dynamics) in asthma patients. T and V parameters were then significantly decreased, but seemed sufficient for successful DPI performance. Both exhalation to RV and incomplete exhalation halfway to RV preceding inhalation allow for effective usage of low-resistance DPI.
Keyphrases
- mycobacterium tuberculosis
- end stage renal disease
- lung function
- drug delivery
- chronic obstructive pulmonary disease
- ejection fraction
- newly diagnosed
- chronic kidney disease
- prognostic factors
- peritoneal dialysis
- case report
- magnetic resonance imaging
- cystic fibrosis
- intensive care unit
- wastewater treatment
- data analysis
- contrast enhanced
- acute respiratory distress syndrome
- extracorporeal membrane oxygenation
- patient reported