Nasal Prongs: Risks, Injuries Incidence and Preventive Approaches Associated with Their Use in Newborns.
Débora de Fátima Camillo RibeiroFrieda Saicla BarrosBeatriz Luci FernandesAdriane Muller NakatoPercy NohamaPublished in: Journal of multidisciplinary healthcare (2020)
The inappropriate prong size, interface reuse, prong model, prolonged NIV use with binasal prong and incorrect prong and NIV circuit position may be associated with the high occurrence of injury in the NICU studied. Simple approaches concerning clinical staff care actions towards the newborn in NIV, which do not require a financial investment, can prevent nasal injury.