Login / Signup

The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

Jan TheopoldStefan SchleifenbaumAlexander GeorgiMichael SchmidtRalf HenkelmannGeorg OsterhoffPierre Hepp
Published in: Archives of orthopaedic and trauma surgery (2020)
The presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.
Keyphrases
  • anterior cruciate ligament
  • molecularly imprinted
  • anterior cruciate ligament reconstruction
  • rotator cuff
  • liquid chromatography