Login / Signup

On the Use of Pulsed UV or Visible Light Activated Gas Sensing of Reducing and Oxidising Species with WO3 and WS2 Nanomaterials.

Ernesto GonzálezJuan Casanova-ChaferAanchal AlaghAlfonso RomeroXavier VilanovaSelene AcostaDamien CossementCarla BittencourtEduard Llobet
Published in: Sensors (Basel, Switzerland) (2021)
This paper presents a methodology to quantify oxidizing and reducing gases using n-type and p-type chemiresistive sensors, respectively. Low temperature sensor heating with pulsed UV or visible light modulation is used together with the application of the fast Fourier transform (FFT) to extract sensor response features. These features are further processed via principal component analysis (PCA) and principal component regression (PCR) for achieving gas discrimination and building concentration prediction models with R2 values up to 98% and RMSE values as low as 5% for the total gas concentration range studied. UV and visible light were used to study the influence of the light wavelength in the prediction model performance. We demonstrate that n-type and p-type sensors need to be used together for achieving good quantification of oxidizing and reducing species, respectively, since the semiconductor type defines the prediction model's effectiveness towards an oxidizing or reducing gas. The presented method reduces considerably the total time needed to quantify the gas concentration compared with the results obtained in a previous work. The use of visible light LEDs for performing pulsed light modulation enhances system performance and considerably reduces cost in comparison to previously reported UV light-based approaches.
Keyphrases
  • visible light
  • room temperature
  • systematic review
  • carbon dioxide