Stability Study of an Electrothermally-Actuated MEMS Mirror with Al/SiO2 Bimorphs.

Peng WangYaBing LiuDonglin WangHuan LiuWeiguo LiuHuiKai Xie
Published in: Micromachines (2019)
Electrothermal actuation is one of the main actuation mechanisms and has been employed to make scanning microelectromechanical systems (MEMS) mirrors with large scan range, high fill factor, and low driving voltage, but there exist long-term drifting issues in electrothermal bimorph actuators whose causes are not well understood. In this paper, the stability of an Al / SiO 2 bimorph electrothermal MEMS mirror operated in both static and dynamic scan mode has been studied. Particularly, the angular drifts of the MEMS mirror plate were measured over 90 h at different temperatures in the range of 50 - 150 °C. The experiments show that the temporal drift of the mirror plate orientation largely depends on the temperature of the electrothermal bimorph actuators. Interestingly, it is found that the angular drift changes from falling to rising as the temperature increases. An optimal operating temperature between 75 °C to 100 °C for the MEMS mirror is identified. At this temperature, the MEMS mirror exhibited stable scanning with an angular drift of less than 0.0001 °/h.