Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement.

Sang-Hyup LeeSeunguk OhYoung-Guk KoYong-Joon LeeByeong-Keuk KimSung Jin HongChul-Min AhnJung-Sun KimByeong-Keuk KimKyu Yong KoIksung ChoChi Young ShimGeu Ru HongDoonghoon ChoiMeyong-Ki Hong
Published in: Korean circulation journal (2023)
ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.