Login / Signup

INTRA- AND INTER-OBSERVER AGREEMENT OF PROXIMAL HUMERAL FRACTURES CLASSIFICATIONS IN ADULTS.

Luis Eduardo Plumacher DiazFrancisco Dada NetoLucas LofranoJoão Vitor DA Cruz GarciaMarcos Vinicius Felix SantanaEiffel Tsuyoshi Dobashi
Published in: Acta ortopedica brasileira (2022)
In the second evaluation, intra-observer agreement improved. In the first evaluation, we obtained values of k = 0.724, k = 0.490, and k = 0.599 for the evaluation of the Neer, AO, and AO/OTA classifications. In the second evaluation, the values k = 0.759, k = 0.772, and k = 0.858. Therefore, the evaluations went from moderate to substantial for the AO classification and from moderate to practically perfect for the AO/OTA classification. The level of inter-observer agreement was substantial (0.61-0.80), with k = 0.669, k = 0.715, and k = 0.780 for the Neer, AO, and AO/OTA classifications, respectively.
Keyphrases
  • machine learning
  • deep learning
  • high intensity