Paradoxical sinus deceleration during dobutamine stress echocardiography: case series and review of the literature.

Enxhela SuloEinar Skulstad DavidsenMai Tone LønnebakkenØyvind BleieSahrai Saeed
Published in: European heart journal. Case reports (2022)
Paradoxical sinus deceleration occurred mostly at maximal dobutamine infusion was accompanied with a decline in blood pressure and resolved spontaneously following cessation of dobutamine infusion. Individuals experiencing paradoxical sinus deceleration had in common abnormal left ventricle geometry but differed with regard to age, sex, and cardiometabolic risk factors.