Comparison of Virtual Intersection and Occlusal Contacts between Intraoral and Laboratory Scans: An In-Vivo Study.
Florian BeckStefan LettnerLana Zupancic CepicAndreas SchedlePublished in: Journal of clinical medicine (2023)
Intersections in the area of occlusal contact points are a phenomenon restricted to virtual casts, which should be considered in CAD/CAM. Initial alignments of LS are less affected by this virtual phenomenon, and contact points may be more distinct according to their anatomic region compared to IOS. Furthermore, intersections can be rectified in a 3D software by adjustment of the maxillomandibular relationship.
Keyphrases