The evaluation of right ventricular systolic function in patients with repaired Tetralogy of Fallot by conventional echocardiographic methods and speckle tracking echocardiography: Compared with the gold standard cardiac mangenetic resonance.
Ahmet Vedat KavurtFeyza Ayşenur PaçSerhat KocaAjda Mutlu MıhçıoğluHasan YiğitPublished in: Echocardiography (Mount Kisco, N.Y.) (2019)
RVGLS is an easy, effective, feasible, and reproducible tool in the evaluation of RV systolic function. So, RVGLS measurement by STE may be one of the routine echocardiographic parameters in the evaluation of RV systolic function in patients with repaired TOF.