Reliability of the Garden Alignment Index and Valgus Tilt Measurement for Nondisplaced Femoral Neck Fractures.
Yasuaki YamakawaNorio YamamotoYosuke TomitaRyuichiro OkudaYasutaka MasadaAkihiro ShiroshitaToshiyuki MatsumotoPublished in: Journal of personalized medicine (2022)
Anteroposterior (AP) alignment assessment for nondisplaced femoral neck fractures is important for determining the treatment strategy and predicting postoperative outcomes. AP alignment is generally measured using the Garden alignment index (GAI). However, its reliability remains unknown. We compared the reliability of GAI and a new AP alignment measurement (valgus tilt measurement [VTM]) using preoperative AP radiographs of nondisplaced femoral neck fractures. The study was designed as an intra- and inter-rater reliability analysis. The raters were four trauma surgeons who assessed 50 images twice. The main outcome was the intraclass correlation coefficient (ICC). To calculate intra- and inter-rater reliability, we used a mixed-effects model considering rater, patient, and time. The overall ICC (95% CI) of GAI and VTM for intra-rater reliability was 0.92 (0.89-0.94) and 0.86 (0.82-0.89), respectively. The overall ICC of GAI and VTM for inter-rater reliability was 0.92 (0.89-0.95), and 0.85 (0.81-0.88), respectively. The intra- and inter-rater reliability of GAI was higher in patients aged <80 years than in patients aged ≥80 years. Our results showed that GAI is a more reliable measurement method than VTM, although both are reliable. Variations in patient age should be considered in GAI measurements.