Calcium Ions Turn on the Fluorescence of Oxytetracycline for Sensitive and Selective Detection.
Hongxia ChenJunxiang PengLong YuHui ChenMingtai SunZhenli SunRunyan NiKhalid A AlamryHadi M MarwaniSuhua WangPublished in: Journal of fluorescence (2020)
Herein, we report an interesting finding about the new application of oxytetracycline (OTC), as a fluorescent probe for the detection of calcium ion (Ca2+), which proved that it can offer an expeditious, highly sensitive, and selective detection method for Ca2+. Upon the addition of Ca2+, the fluorescence of OTC could be significantly enhanced with rapid response and high sensitivity, and achieved a good limit of detection as low as 125 nM in aqueous solution. The complex formed via Ca2+ coordinating to the hydroxyl group of OTC contributes to the fluorescence enhancement, which has been proved by several characterization methods including UV-vis analysis, binding constant determination, and fluorescence titration. The method avoided complexity for EDTA measurement of Ca2+ in running water as proposed previously. Taking advantage of good availability, stability and operability, the OTC was further successfully applied to the detection of Ca2+ in a real environment. Graphical Abstract.