Prediction of blood volume to be processed to achieve a target number of CD34+ cells: Development, validation and implementation of a formula.
Irene García GarcíaJoan CidGemma Moreno-JiménezMaría Tenorio NúñezAna Jiménez MartínAna Vallés CarbonerasKyra Velázquez-KennedyMiguel LozanoFrancisco-Javier López-JiménezPublished in: Vox sanguinis (2023)
Formula calculations were accurate. Formula implementation allowed the optimization of the procedures and reduced the rate of individuals in need of apheresis for more than 1 day.