Evaluation of the single medial circummuscular perforator DIEP flap: Outcomes and comparison to traditional transmuscular single perforator flap.

Jessica F RoseDmitry ZavlinAmanda E GarrettVishwanath ChegireddyWarren A Ellsworth
Published in: Microsurgery (2017)
Based on our findings, using a medial wraparound perforator is a safe and reliable option when compared with a single transmuscular perforator DIEP flap. Choosing the wraparound perforator may show benefit as it eliminates muscular dissection and nerve damage, and tends to minimize fascial incision length.
Keyphrases
  • breast reconstruction
  • type diabetes
  • metabolic syndrome
  • skeletal muscle
  • laparoscopic surgery