A novel extraction-free dual HiFi-LAMP assay for detection of methicillin-sensitive and methicillin-resistant Staphylococcus aureus .
Xiuli ZhaoYi ZengBeibei YanYanping LiuYueqin QianAiping ZhuYongjuan ZhaoXiaoling ZhangChiyu ZhangZhenzhou WanPublished in: Microbiology spectrum (2024)
Staphylococcus aureus ( S. aureus ) is a leading cause of bacteremia and blood stream infections. Methicillin-resistant S. aureus (MRSA) that first appeared in 1961 often caused hospital-acquired infections (HAIs) and community-acquired infections (CAIs) and was associated with high mortality rate. Accurate and rapid point-of-care testing (POCT) of MRSA is crucial for clinical management and treatment of MRSA infections, as well as the prevention and control of HAIs and CAIs. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of methicillin-susceptible S. aureus and MRSA. The dual HiFi-LAMP assay can detect 30 copies/reaction of nuc and mecA genes with detection limits of 147 and 158 copies per 25 µL reaction, respectively. A retrospective clinical evaluation with 107 clinical S. aureus isolates showed both sensitivity and specificity of 100%. A prospective clinical evaluation with 35 clinical samples revealed a specificity of 100% and a sensitivity of 92.3%. The dual HiFi-LAMP assay can detect almost all S. aureus samples (141/142; 99.3%) within 20 min, implying that the entire HiFi-LAMP assay (including sample process) can be completed within 40 min, extremely significantly shorter than 3-5 days by the traditional clinical microbial culture and antibiotic susceptibility testing. The novel extraction-free dual HiFi-LAMP assay can be used as a robust POCT tool to promote precise diagnosis and treatment of MRSA infections in hospitals and to facilitate surveillance of MRSA at hospital and community settings.IMPORTANCEMethicillin-resistant Staphylococcus aureus (MRSA) was associated with high mortality rate and listed as a "priority pathogen" by the World Health Organization. Accurate and rapid point-of-care testing (POCT) of MRSA is critically required for clinical management and treatment of MRSA infections. Some previous LAMP-based POCT assays for MRSA might be questionable due to their low specificity and the lack of appropriate evaluation directly using clinical samples. Furthermore, they are relatively tedious and time-consuming because they require DNA extraction and lack multiplex detection capacity. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of MRSA and methicillin-susceptible S. aureus . The assay has high specificity and sensitivity and can be completed within 40 min. Clinical evaluation with real clinical samples and clinical isolates showed excellent performance with 100% specificity and 92.3%-100% sensitivity. The novel extraction-free assay may be a robust POCT tool to promote precise diagnosis of MRSA infections and facilitate surveillance of MRSA at hospital and community settings.
Keyphrases
- methicillin resistant staphylococcus aureus
- loop mediated isothermal amplification
- staphylococcus aureus
- high throughput
- clinical evaluation
- sensitive detection
- healthcare
- biofilm formation
- mental health
- emergency department
- public health
- cardiovascular disease
- risk factors
- real time pcr
- pseudomonas aeruginosa
- escherichia coli
- type diabetes
- high resolution
- dna methylation
- adverse drug
- genome wide
- structural basis
- quantum dots
- single molecule
- cell free
- multidrug resistant
- cystic fibrosis