Login / Signup

Inhomogeneous terminators on the exoplanet WASP-39 b.

Néstor EspinozaMaria E SteinrueckJames KirkRyan J MacDonaldArjun B SavelKenneth E ArnoldEliza M-R KemptonMatthew M MurphyLudmila CaroneMaria ZamyatinaDavid A LewisDominic SamraSven KieferEmily RauscherDuncan ChristieNathan J MayneChristiane HellingZafar RustamkulovVivien ParmentierErin M MayAarynn L CarterXi ZhangMercedes López-MoralesNatalie AllenJasmina BlecicLeen DecinLuigi ManciniKaran MolaverdikhaniBenjamin V RackhamEnric PalleShang-Min TsaiEva-Maria AhrerJacob L BeanIan J M CrossfieldDavid HaegeleEric HébrardLaura KreidbergDiana PowellAaron D SchneiderLuis WelbanksPeter J WheatleyRafael BrahmNicolas Crouzet
Published in: Nature (2024)
Transmission spectroscopy has been a workhorse technique used over the past two decades to constrain the physical and chemical properties of exoplanet atmospheres 1-5 . One of its classical key assumptions is that the portion of the atmosphere it probes-the terminator region-is homogeneous. Several works from the past decade, however, have put this into question for highly irradiated, hot (T eq  ≳ 1,000 K) gas giant exoplanets, both empirically 6-10 and through three-dimensional modelling 11-17 . While models have predicted clear differences between the evening (day-to-night) and morning (night-to-day) terminators, direct morning and evening transmission spectra in a wide wavelength range have not been reported for an exoplanet so far. Under the assumption of precise and accurate orbital parameters for the exoplanet WASP-39 b, here we report the detection of inhomogeneous terminators on WASP-39 b, which has allowed us to retrieve its morning and evening transmission spectra in the near-infrared (2-5 μm) using the James Webb Space Telescope. We have observed larger transit depths in the evening, which are, on average, 405 ± 88 ppm larger than the morning ones, and also have qualitatively larger features than the morning spectrum. The spectra are best explained by models in which the evening terminator is hotter than the morning terminator by 17 7 - 57 + 65  K, with both terminators having C/O ratios consistent with solar. General circulation models predict temperature differences broadly consistent with the above value and point towards a cloudy morning terminator and a clearer evening terminator.
Keyphrases
  • high resolution
  • physical activity
  • mental health
  • small molecule
  • single molecule
  • photodynamic therapy
  • fluorescence imaging
  • rare case