Evaluating Diagnostic Tests for Helicobacter pylori Infection Without a Reference Standard: Use of Latent Class Analysis.

Dong Wook JekarlHyunyu ChoiJi Yeon KimSeungok LeeChung Hyun TaeHae Kyung LeeYonggoo Kim
Published in: Annals of laboratory medicine (2020)
Evaluation of diagnostic tests requires reference standards, which are often unavailable. Latent class analysis (LCA) can be used to evaluate diagnostic tests without reference standards, using a combination of observed and estimated results. Conditionally independent diagnostic tests for Helicobacter pylori infection are required. We used LCA to construct a reference standard and evaluate the capability of non-invasive tests (stool antigen test and serum antibody test) to diagnose H. pylori infection compared with the conventional method, where histology is the reference standard. A total of 96 healthy subjects with endoscopy histology results were enrolled from January to July 2016. Sensitivity and specificity were determined for the LCA approach (i.e., using a combination of three tests as the reference standard) and the conventional method. When LCA was used, sensitivity and specificity were 83.8% and 99.4% for histology, 80.0% and 81.9% for the stool antigen test, and 63.6% and 89.3% for the serum antibody test, respectively. When the conventional method was used, sensitivity and specificity were 75.8% and 71.1% for the stool antigen test and 77.7% and 60.7% for the serum antibody test, respectively. LCA can be applied to evaluate diagnostic tests that lack a reference standard.