Reply to the Comment on "Understanding the Increasing Trend of Sensor Signal with Decreasing Oxygen Partial Pressure by a Sensing-Reaction Model Based on O 2- Species".

Liupeng ZhaoXueqin GongWei TaoTianshuang WangPeng SunFangmeng LiuXishuang LiangFengmin LiuGeyu Lu
Published in: ACS sensors (2023)
In our recent work ( ACS Sens. 2022 , 7 , 1095-1104), Mirabella et al. provided comments on our publication, mainly focusing on the controversy between the oxygen vacancy model and the ionosorbed model and the related derivation based on the law of mass action. Herein we explain the correlation between the ionosorption model and the oxygen vacancy model and provide a brief introduction of our view on these two models. Moreover, a more detailed derivation about the law of mass action is provided to explain the relationship between surface electron concentration, oxygen partial pressure, adsorbed oxygen density, and oxygen vacancy density.
Keyphrases
  • acute coronary syndrome
  • drug induced