Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-l-lactide mesh versus titanium miniplate.
Young-Wook ParkHyun-Sik KangJang-Ha LeePublished in: Maxillofacial plastic and reconstructive surgery (2019)
The HA/PLLA mesh-fixation group demonstrated superior long-term skeletal stability with respect to the position of mandible, when compared with the titanium-fixation group.