One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
Alejandro Rodriguez-RuizAlbert Gubern-MeridaMechli Imhof-TasSusanne LardenoijeAlexander J T WandersIngvar AnderssonSophia ZackrissonKristina LångMagnus DustlerNico KarssemeijerRitse M MannIoannis SechopoulosPublished in: European radiology (2017)
• One-view breast tomosynthesis is not inferior to two-view digital mammography. • One-view DBT is not inferior to 2-view DM plus 2-view DBT. • Training may lead to 1v-DBT being sufficient for screening.