Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy.
Xin XinChuandong ChengChurong LiJie LiPei WangGang YinJinyi LangPublished in: Cancer management and research (2020)
Nasopharyngeal carcinoma IMRT plans made by an automatic planning tool met the clinical requirements for target prescription dose; moreover, the dose of normal tissues was lower than in MA plans. Clinical physicists' time can be saved and the influence of factors such as the lack of experience in treatment planning can be avoided.