Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe 2+ or Fe 3+ Ions.

Rimeh IsmailIvana ŠeděnkováZulfiya ČernochováIryna RomanenkoOgnen Pop-GeorgievskiMartin HrubýElena Tomšík
Published in: Biosensors (2022)
We constructed a sensor for the determination of Fe 2+ and/or Fe 3+ ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazoline)s layer. We have shown that our potentiometric sensing layers show a rapid response to the presence of Fe 2+ or Fe 3+ ions, do not experience interference with other ions (such as Cu 2+ ), and work in a biological environment in the presence of bovine serum albumin (as a model serum protein). The sensing layers detect iron ions in the concentration range from 5 nM to 50 µM.
Keyphrases