Duration-dependent margins for prostate radiotherapy-a practical motion mitigation strategy.
Eric Pei Ping PangKellie KnightSung Yong ParkWeixiang LianZubin MasterMarilyn BairdJason Wei Xiang ChanMichael Lian Chek WangTerence Wee Kiat TanMelvin L K ChuaEu Tiong ChuaWen Shen LooiWen Long NeiJeffrey Kit Loong TuanPublished in: Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] (2020)
We report our experience in deriving the minimum duration-dependant margin to generate the required planning target volume for prostate radiotherapy. The required margin increases linearly in all directions within the 15-min duration; thus, the margin will depend on the duration of the technique chosen (IMRT/VMAT/3DCRT/proton).