Bicuspid aortic valve repair with hemi-remodeling technique and external ring annuloplasty.
Carlotta BregaMustafa ZakkarPavel ZacekMichele PalladinoEmmanuel LansacPublished in: Journal of cardiac surgery (2019)
The standardized modified hemi-remodeling technique we present is a safe and reproducible procedure, with satisfactory durability at follow-up. This technique represents an interesting alternative to full valve sparing root replacement, as it avoids the operative risk of coronary reimplantation, allows shorter cross-clamping time and a better exposition on the valve for a symmetrical repair, placing the commissure at 180°, compared with valve sparing root replacement.