Login / Signup

Workplace exposure to carbon dioxide during routine laparoscopy - is it safe?

Malin Af PetersensFritiof Andersson Fenger-KrogJan G Jakobsson
Published in: F1000Research (2020)
Background: Minimally invasive surgeries have increased dramatically during the last decades. Carbon dioxide (CO 2) is the gas used for insufflation during laparoscopies, creating space and visibility. The CO 2 leaks into ambient air through ports where instruments are inserted. If the CO 2 reaches a certain concentration it affects personnel health. There are national occupational exposure limits (OEL) for CO 2, including a level limit value (LLV) of 5000 ppm. We are not aware of any previous studies addressing occupational exposure to CO 2 during laparoscopies. The aim of this study was to assess the compliance to national OELs for CO 2 during laparoscopies. Methods: A gas detector was placed in the breathing zone of personnel in the operating theatre. The detector measured CO 2 concentrations every tenth minute during laparoscopies in three locations. Results: During 27 laparoscopies, the measured CO 2 reached a maximum concentration of 1100 ppm, less than one fourth of the LLV. Median CO 2 concentration was 700 ppm. Conclusion: Results show that the occupational exposure to CO 2 during laparoscopies is well below set OELs. Our findings support personnel safety associated with routine use of CO 2 during laparoscopies.
Keyphrases