Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients.

Ha-Yeon KimSung Yeon HamEun Jung KimHei Jin YoonSeung Yeon ChoiBon Nyeo Koo
Published in: Yonsei medical journal (2021)
Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation.