Login / Signup

Temperature Characteristics of Traditional Indirect Moxibustion and Electronic Moxibustion.

Dong-Joo KimHyo-Rim JoHansol JangSeong-Kyeong ChoiChan Yung JungWon-Suk SungSeung-Deok LeeByung-Wook LeeEun-Jung Kim
Published in: Journal of acupuncture and meridian studies (2022)
TIM resulted in a higher temperature rise compared to EM at the surface and at a 2 mm depth reaching over 50℃, which creates risk of burns. Thermal stimulation with EM had a lower risk of burns with temperature increment not being statistically different from TIM below the depth of 5 mm.
Keyphrases
  • optical coherence tomography