This study demonstrated
that three-dimensional MDEIT for neural imaging is feasible and that MDEIT
reconstructed superior images to EIT, which can be explained by the lesser rank
deficiency of the MDEIT Jacobian. Reconstructions of a perturbation in a saline
tank demonstrated a proof of principle for two-dimensional MDEIT with OPMs
and identified the best reconstruction algorithm.