[Change of corneal radii after Descemet membrane endothelial keratoplasty measured by optical coherence tomography and Scheimpflug tomography].
Raphael DienerNicole EterMaged AlnawaisehPublished in: Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft (2020)
Both Scheimpflug and OCT showed a significant decrease in the radius of the posterior corneal surface after DMEK. The postoperative measurements showed a higher agreement between the devices than those performed preoperatively.