Goal-Driven Beam Setting Optimization for Whole-Breast Radiation Therapy.
Wentao WangYang ShengSua YooRachel C BlitzblauFang-Fang YinQ Jackie WuPublished in: Technology in cancer research & treatment (2019)
We developed an automated goal-driven beam setting optimization program for whole-breast radiation therapy. It provides clinically relevant solutions based on previous clinical practice as well as patient specific anatomy on a substantially faster time frame.