Application and comparison of lyophilisation protocols to enhance stable long-term storage of filovirus pseudotypes for use in antibody neutralisation tests.
Martin Mayora NetoEdward WrightNigel J TempertonPeter SoemaRimko Ten HaveIvo PloemenSimon D ScottPublished in: Journal of applied microbiology (2023)
Filovirus PVs are amenable to lyophilisation and can be stored for at least 2 years in a household fridge to be used in antibody assays. Lyophilisation performed in the right conditions would allow transportation at room temperature, even in warmer climates.