Login / Signup

XEN Glaucoma Implant for the Management of Glaucoma in Naïve Patients versus Patients with Previous Glaucoma Surgery.

Katarzyna LewczukJoanna KonopinskaJoanna JabłońskaJacek RudowiczPatrycja LaszewiczDiana Anna DmuchowskaZofia MariakMarek Rekas
Published in: Journal of clinical medicine (2021)
This retrospective study analyzed the surgical and refractive outcomes of a XEN Gel Implant (Allergan, Abbvie Company, Irvine, CA, USA) in naïve patients versus those with previous glaucoma surgery. We evaluated the efficacy of XEN implantation in 86 glaucoma patients during a long-term follow-up period. Patients were divided into two groups: naïve patients (Group 1) and patients with previous glaucoma surgery (Group 2). Eyes that received a XEN Gel Stent placement from December 2014 to October 2019 were included. Intraocular pressure (IOP) change, corrected distance visual acuity (CDVA), change in glaucoma medications, frequency of slit lamp revision procedures, and frequency of secondary glaucoma surgeries were the primary outcomes. In Group 1, the mean IOP before surgery was decreased significantly from 25.00 ± 7.52 mmHg to 16.83 ± 5.12 mmHg by the end of the study. In Group 2, the mean IOP decreased significantly from 25.35 ± 7.81 mmHg to 17.54 ± 5.34 mmHg. The mean IOP decrease from baseline was 29% in Group 1 and 27% in Group 2 (p = 0.567). There were no significant differences between the groups in the IOP baseline level, the final level, or the change between preoperative and final levels. The qualified success rate for Group 2 was 68.7% versus 76.5% for Group 1 for the initial procedure and 15.4% vs. 20.2%, respectively, for complete success rate (p > 0.05). However, at the end of the follow-up, more patients achieved an IOP < 18 mmHg in Group 1 than in Group 2. Despite the need for more anti-glaucoma medications, repeat XEN Gel implantation appears to show promising results in patients with previously failed anti-glaucoma procedures, owing to its minimal invasiveness.
Keyphrases