[Simultaneous determination of 10 quaternary ammonium salt bactericides in oral care products by high performance liquid chromatography-evaporative light-scattering detection].
Juan TangYou-Chao DingXiao-Qing FeiBin WuZhi-Juan QianShan-Dan ChenBai LiPublished in: Se pu = Chinese journal of chromatography (2024)
Quaternary ammonium salt bactericides are broad-spectrum bactericides often used in oral care products because of their high antibacterial efficacy, strong penetration, and low toxicity. However, the excessive use of quaternary ammonium salt bactericides may cause contact dermatitis, scalding poisoning, and even death. Existing methods to determine quaternary ammonium salt bactericides are unable to meet current requirements owing to the lack of determination components. Therefore, establishing a simple and accurate method for the simultaneous detection of more quaternary ammonium salt bactericides is necessary. In this study, a method that couples sample pretreatment with high performance liquid chromatography-evaporative light-scattering detection (HPLC-ELSD) was developed for the simultaneous determination of quaternary ammonium salt bactericides in oral care products, including dodecyltrimethylammonium chloride, dodecyldimethylbenzylammonium chloride, benzethonium chloride, tetradecyl trimethyl ammonium chloride, tetradecyldimethylbenzylammonium chloride, N -hexadecyltrimethylammonium chloride, benzyldimethylhexadecylammonium chloride, trimethylstearylammonium chloride, stearyldimethylbenzylammonium chloride, and docosyltrimethylammonium chloride. Some of these bactericides do not absorb ultraviolet light, so a universal evaporative light-scattering detector was used owing to testing cost and stability concerns. The paste samples contained thickening agents, which are highly soluble in water but insoluble in organic solvents; these agents can seriously affect the results of sample pretreatment and damage the chromatographic column. Hence, sample dehydration was necessary. In this study, four dehydration methods were compared. Anhydrous sodium sulfate (Na 2 SO 4 ) was selected, and the amount of Na 2 SO 4 was optimized. Based on the solubility of the 10 target compounds and extraction efficiency, three extraction solvents were compared, and ethanol was selected. Ultrasonic extraction was the primary extraction process used in this study. The effects of different ultrasonication times, temperatures, and powers on the extraction recoveries were also investigated. Ultimately, the optimized conditions were as follows: extraction of the dehydrated paste and powder samples using ethanol at room temperature (25 ℃) for 20 min under 100 W ultrasound power, and dilution of the liquid sample with ethanol. After extraction, the samples were separated on an Acclaim Surfactant column (150 mm×4.6 mm, 5 μm) with 50 mmol/L ammonium acetate aqueous solution (pH=5.5) (A) and acetonitrile (B) as mobile phases. The gradient elution program were as follows: 0-5.0 min, 75%A-35%A, 5.0-15.0 min, 35%A-20%A, 15.0-20.0 min, 20%A, 20.0-21.0 min, 20%A-75%A, 21.0-25.0 min, 75%A. An external standard method was used for quantitative determination. The 10 compounds were analyzed within 25 min. Linear equations, correlation coefficients, and linear ranges were obtained by analyzing a series of mixed standard working solutions. The limits of detection (LODs, S/N =3) and quantification (LOQs, S/N =10) of the 10 components were determined. Stearyldimethylbenzylammonium chloride and docosyltrimethylammonium chloride showed good linear relationships in the range of 10-200 mg/L, while the other compounds demonstrated good linear relationships in the range of 5-100 mg/L. In all cases, correlation coefficients ( R 2 ) of no less than 0.9992 were obtained. The LODs and LOQs were in the range of 1.42-3.31 mg/L and 4.25-9.94 mg/L, respectively. Ten analytes were spiked in blank matrices, such as toothpaste (paste), mouthwash (liquid), and dentifrice powder (powder) at three levels, and the recoveries and precisions were calculated. The average recoveries were 87.9%-103.1%, and the corresponding relative standard deviations (RSDs) did not exceed 5.5% ( n =6). The developed method was used to detect 109 oral care products. Benzyldimethylhexadecylammonium chloride and stearyldimethylbenzylammonium chloride revealed high detection rates. Moreover, the amount of stearyldimethylbenzylammonium chloride in one toothpaste sample exceeded regulatory requirements. Given its advantages of good precision and accuracy, the developed method is suitable for the quantitative analysis of the 10 aforementioned compounds in typical oral care products. The study findings can serve as a reference for the quality and safety monitoring of oral care products.
Keyphrases
- simultaneous determination
- high performance liquid chromatography
- solid phase extraction
- ionic liquid
- tandem mass spectrometry
- healthcare
- liquid chromatography tandem mass spectrometry
- quality improvement
- palliative care
- liquid chromatography
- ultra high performance liquid chromatography
- room temperature
- molecularly imprinted
- magnetic resonance imaging
- ms ms
- loop mediated isothermal amplification
- high resolution
- body mass index
- pain management
- magnetic resonance
- single cell
- real time pcr
- aqueous solution
- atomic force microscopy