Point-of-care testing with high-sensitivity cardiac troponin assays: the challenges and opportunities.

Louise Ann CullenPaul O CollinsonEvangelos Giannitsis
Published in: Emergency medicine journal : EMJ (2022)
Methods to improve the safety, accuracy and efficiency of assessment of patients with suspected acute coronary symptoms have occupied decades of study and have supported significant changes in clinical practice. Much of the progress is reliant on results of laboratory-based high-sensitivity cardiac troponin assays that can detect low concentrations with high precision. Until recently, point-of-care (POC) platforms were unable to perform with similar analytical precision as laboratory-based assays, and recommendations for their use in accelerated assessment strategies for patients with suspected acute coronary syndrome has been limited. As POC assays can provide troponin results within 20 min, and can be used proximate to patient care, improvements in the efficiency of assessment of patients with suspected acute coronary syndrome is possible, particularly with new high-sensitivity assays.
Keyphrases
  • acute coronary syndrome
  • high throughput
  • clinical practice
  • percutaneous coronary intervention
  • coronary artery disease
  • liver failure
  • heart failure
  • left ventricular