Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture.
Yung-Cheng ChiuTsung-Yu HoCheng-En HsuYen-Nien TingMing-Tzu TsaiJui-Ting HsuPublished in: Journal of orthopaedic surgery and research (2022)
Compared with bone plate fixation, double lag screw fixation yielded slightly lower maximum bearable fracture force but similar stiffness. Therefore, this technique could be used for treating oblique metacarpal shaft fractures. However, using double lag screw fixation alone is technically demanding and requires considerable surgical experiences to produce consistent results.