Login / Signup

Evaluating xanthochromia in the diagnosis of subarachnoid haemorrhage in Scotland in the Era of modern computed tomography.

Stephen RankinJacqueline McGuireMohamed ChekroudLikhith AlakandyBabu Mukhopadhyay
Published in: Scottish medical journal (2022)
The positive yield of xanthochromia is low but identified 6% of SAH. NEQAS-spectrophotometry is an excellent diagnostic method with 100% sensitivity, 99% specificity. Incorporating RCC markedly reduces false positive and inconclusive tests reducing need for further imaging.
Keyphrases
  • computed tomography
  • high resolution
  • positron emission tomography
  • magnetic resonance imaging
  • magnetic resonance
  • mass spectrometry
  • structural basis