Increased mid-abdominal circumference is a predictor for surgical wound complications in kidney transplant recipients: A prospective cohort study.
Mohamed TahaNiall Francis DavisRichard PowerPonusamy MohanJames FordeGordon SmythDilly M LittlePublished in: Clinical transplantation (2017)
Kidney transplant recipients are at an increased risk of developing surgical site wound complications due to their immunosuppressed status. We aimed to determine whether increased mid-abdominal circumference (MAC) is predictive for wound complications in transplant recipients. A prospective study was performed on all kidney transplant recipients from October 2014 to October 2015. "Controls" consisted of kidney transplant recipients without a surgical site wound complication and "cases" consisted of recipients that developed a wound complication. In total, 144 patients underwent kidney transplantation and 107 patients met inclusion criteria. Postoperative wound complications were documented in 28 (26%) patients. Patients that developed a wound complication had a significantly greater MAC, body mass index (BMI), and body weight upon renal transplantation (P<.001, P=.011, and P=.011, respectively). On single and multiple logistic regression analyses, MAC was a significant predictor for developing a surgical wound complication (P=.02). Delayed graft function and a history of preformed anti-HLA antibodies were also predictive for surgical wound complications (P=.003 and P=.014, respectively). Increased MAC is a significant predictor for surgical wound complications in kidney transplant recipients. Integrating clinical methods for measuring visceral adiposity may be useful for stratifying kidney transplant recipients with an increased risk of a surgical wound complication.