[Comparison of cervical fusion with autografting of fibula vs titanium cage].
Gerardo de Jesús Franco-RamírezFrancisco Cabrales-GarcíaFrancisco Godínez-GarcíaPublished in: Revista medica del Instituto Mexicano del Seguro Social (2023)
The use of autologous fibular graft offers a better rate of fusion and subsidence compared to the titanium cage, as well as similar functional results at 3 months of follow-up. It represents an excellent treatment option for cervical spondylosis.