Comparative Study of Small vessel (under 0.8mm) Anastomosed Free flap and Larger vessel (over 0.8mm) Anastomosed Free Flap; Does Supermicrosurgery provide sufficient blood flow to the free flap?

Hyung Bae KimJoon Pio Jp HongHyunsuk Peter Suh
Published in: Journal of reconstructive microsurgery (2023)
Small-vessel (<0.8 mm) free flaps showed similar flow velocity and flow volume to larger-vessel (>0.8 mm) anastomosed free flaps. Blood flow to the small-vessel anastomosed free flap was sufficient despite its small-vessel size.
Keyphrases
  • blood flow