Efficacy of Vaporized Hydrogen Peroxide Combined with Silver Ions against Multidrug-Resistant Gram-Negative and Gram-Positive Clinical Isolates.
Sandra Patricia Rivera-SanchezJosé María Rojas-AbadíaJohn Jairo Ríos-AcevedoAna Fernanda Mejía-HurtadoLuz Natalia Espinosa-MoyaIvan Darío Ocampo-IbáñezPublished in: International journal of molecular sciences (2022)
Antimicrobial resistance (AMR) is a serious public health problem that results in high morbidity and mortality rates. In particular, multidrug-resistant (MDR) strains circulating in hospital settings pose a major threat as they are associated with serious nosocomial infections. Therefore, regular cleaning and disinfection procedures, usually using chemical disinfectants, must be implemented in these facilities. Hydrogen peroxide (HP)-based disinfectants have proven high microbicidal activity and several comparative advantages over conventional disinfectants. We assessed the in vitro biocidal activity of an 8% HP solution combined with 30 mg/L silver ions (HP + Ag) against MDR clinical isolates of Klebsiella pneumoniae (MDRKp) and Pseudomonas aeruginosa (MDRPa), and methicillin-resistant Staphylococcus aureus (MRSA). Accordingly, the in vitro antibacterial activity was determined using the macrodilution method, and the efficacy was determined for 30 min in terms of (1) activity on bacteria in suspension and (2) activity on surfaces using vaporized HP + Ag on a 20 cm2 stainless steel surface. A strong bactericidal effect of HP + Ag was observed against MDRKp, MDRPa, and MRSA strains, with minimum inhibitory concentrations and minimum bactericidal concentrations between 362.5 and 5800 mg/L. A strong effect was observed during the 30 min of HP + Ag exposure to the resistant clinical isolates, with over 4-Log10 reduction in CFUs. Regarding the efficacy of the disinfectant on surfaces, bacterial load reductions of >99% were observed. These results suggest that HP + Ag is potentially useful as an effective disinfectant for decontaminating surfaces in hospital settings suspected of contamination with MDR bacteria.
Keyphrases
- multidrug resistant
- gram negative
- hydrogen peroxide
- klebsiella pneumoniae
- methicillin resistant staphylococcus aureus
- acinetobacter baumannii
- drug resistant
- quantum dots
- antimicrobial resistance
- public health
- staphylococcus aureus
- nitric oxide
- pseudomonas aeruginosa
- biofilm formation
- escherichia coli
- gold nanoparticles
- healthcare
- highly efficient
- visible light
- drinking water
- cystic fibrosis
- emergency department
- pulmonary embolism
- electronic health record
- human health
- climate change
- adverse drug
- health risk