Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration.
Elisabeth NeuhausKilian WeissRene BastkowskiJonas KoopmannDavid MaintzDaniel GiesePublished in: Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance (2019)
A six- to eightfold acceleration of 4D flow CMR using CS is feasible. Up to a CS acceleration rate of 6, no statistically significant differences in measured flow parameters could be observed with respect to the reference technique. Acquisitions in patients with aortopathies confirm the potential to integrate the proposed method in a clinical routine setting, whereby its main benefits are scan-time savings and direct on-line reconstruction.