Login / Signup

Diagnostic accuracy of screening tests for patients suspected of COVID-19, a retrospective cohort study.

Marco MorettiJohan Van LaethemDeborah De GeyterWilfried CoolsBart IlsenSabine Danielle AllardDenis Pierard
Published in: Infectious diseases (London, England) (2021)
In this cohort, the sensitivity and specificity of RT-PCR and serology for the diagnosis of CoViD-19 were high and comparable. CCT had the highest sensitivity and confirmed its efficacy as a screening tool. CoViD-19 patients, who have a more severe presentation, might have negative RT-PCR and positive serology results.
Keyphrases
  • sars cov
  • coronavirus disease
  • end stage renal disease
  • ejection fraction
  • newly diagnosed
  • chronic kidney disease
  • respiratory syndrome coronavirus
  • patient reported
  • drug induced