Impact of unknown incidental findings in PET/CT examinations of patients with proven or suspected vascular graft or endograft infections.

Lars HusmannNadia EberhardMartin W HuellnerBruno LedergerberAnna MuellerHannes GruenigMichael MesserliCarlos-A MestresZoran RancicAlexander ZimmermannBarbara Hasse
Published in: Scientific reports (2021)
Vascular graft or endograft Infections (VGEI) are rare but severe complications of vascular reconstructive surgery, and associated with significant mortality and morbidity risk. Positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT) has been shown to have a high diagnostic accuracy in the detection of VGEI. In this single-center prospective cohort study, we assessed the rate and the impact on patient management of relevant unknown incidental findings in PET/CT of patients with proven or suspected VGEI, and clinical follow-up of all patients was performed. Our study results show a comparably high rate of relevant unknown incidental findings (181 in 502 examinations), with documented direct impact on patient management in 80 of 181 (44%) of all findings. PET/CT scan- and patient-based evaluation revealed impact on patient management in 76 of 502 (17%) of all PET/CT scans, and in 59 of 162 (36%) of all patients, respectively. Furthermore, PET/CT correctly identified the final diagnosis in 20 of 36 (56%) patients without VGEI. In conclusion, in proven and suspected VGEI, PET/CT detects a high rate of relevant unknown incidental findings with high impact on patient management.