Sepsis scoring systems and use of the Sepsis six care bundle in maternity hospitals.
Nouf AbutheraaJune GrantAlexander B MullenPublished in: BMC pregnancy and childbirth (2021)
mSIRS and MEWS were quite similar in detecting sepsis when compared to positive culture, with their ability to detect sepsis being close to chance. This underlines the need for creating a valid SSS with high sensitivity and specificity for clinical use in obstetric settings. Clinical use of SSCB was limited despite it being a health board policy, although there is considerable possibility of improvement following detailed audits and removal of barriers for implementing SSCB.