Login / Signup

Early Outcomes of an Artificial Endothelial Replacement Membrane Implantation After Failed Repeat Endothelial Keratoplasty.

Luigi FontanaNatalie di GeronimoMichela CennamoRita MencucciPiera VersuraAntonio Moramarco
Published in: Cornea (2023)
Synthetic endothelial replacement membrane implantation improves central corneal transparency and visual acuity in patients with failed EK and guarded prognosis for repeat keratoplasty. No significant implant-related adverse events occurred after surgery.
Keyphrases
  • endothelial cells
  • optical coherence tomography
  • weight loss
  • drug induced